Measurement Of Selected Pripincal Organic Hazardous Consituent (POHC) In Cement Klin

Idteknologi433
JudulMeasurement Of Selected Pripincal Organic Hazardous Consituent (POHC) In Cement Klin
AbstrakThis paper presents the measurement of a selected principal organic hazardous constituent (POHC) injected into cement kiln that burned waste derived synthetic fuel. The POHC selected for the test was tetrachloroethane (more commonly known as perchloroethylene, or just PERC). The conditions of the kiln tested were maintained at its normal operation.The results will be used to calculate a destruction and removal efficiency (DRE) capability of that cement kiln. Thus, the test was assumed to be able to simulate the performance of a cement kiln acting as a waste combustor in destructing toxic waste. The test protocol was based upon the full set of procedures mandated by United States Environmental Protection Agency (USEPA) designed to demonstrate sufficient destruction of organic constituents, by demonstrating a 99.9999% DRE. It was found that all measurement data of POHC resulted DRE values higher than the limit of 99.9999%. As a conclusion, the cement kiln test has demonstrated the capability for achieving performance required for incineration of organic constituents.
KatakunciPOHC, PERC, waste derived synthetic fuel, kiln
Kategori7
MediamasaJurnal Teknologi Lingkungan Edisi Khusus 1 "Hari Lingkungan Hidup 2006"
Alamatlinkhttp://www.kelair.bppt.go.id/Jtl/2006/khusus1/
PenulisKardono
Instansi
Emailair@webmail.bppt.go.id
Url
Keterangan