Abstrak | The concentration of soft drink contains organic waste water not so high. There fore one of the alternative of processing technology is used aerobic system: Oxydation ditch. On this observation can be seen that the system is able to degrade the organic matter by observe the operation parameters process to operate the system and the parameters are BOD, COD, TSS, Oil & grease, TDS, Total N and pH. All parameters show stability process during 3 (three) months operation. Base on the criteria as mentioned above, the efficiency that can be reached by this system are around 96,875 % for BOD efficiency, COD 96 % for COD efficiency , TSS 80 %, Oil & grease 75 %, Total N 76,92 % and pH 41 %. |